Power table
Hydrozon® gas produces the flame which is
delivered through the torch handle through the torch tip. Flame size is regulated by the quantity of gas produced, torch handle valve and diameter of the torch tip (e.g. G20 = 20; the smaller torch tip number, the larger the flame). |
The following table shows the number of stations that can be served by each machine based upon the torch tip number and corresponding handles used. |
Type | G14 | G16 | G17 | G18 | G19 | G20 | G21 | G22 | G23 | G24 | G25 | G26 |
1 LEs | - | - | - | - | - | - | - | 1 | 1 | 2 | 3 | 4 |
50s | - | - | - | - | - | - | - | 1 | 1 | 2 | 3 | 4 |
2 LEs | - | - | - | - | - | - | 1 | 2 | 3 | 4 | 5 | 6 |
100s+digital | - | - | - | - | - | 1 | 1 | 2 | 3 | 4 | 5 | 6 |
3LE | - | - | - | 1 | 1 | 2 | 3 | 4 | 5 | 7 | 8 | 9 |
200sp | - | - | 1*) | 1 | 1 | 2 | 3 | 4 | 5 | 7 | 8 | 9 |
4 LE | 1*) | 1 | 1 | 2*) | 2 | 3 | 4 | 5 | 7 | 9 | 10 | 12 |
400s | 1 | 2*) | 2 | 3 | 4 | 5 | 6 | 8 | 10 | 12 | 15 | 20 |
*) for short periods of time
Type | G14 | G16 | G17 | G18 | G19 | G20 | G21 | G22 | G23 | G24 | G25 | G26 |
Diameter (m) | 1.5*10-3 | 1.1*10-3 | 1.0*10-3 | 8.0*10-4 | 6.5*10-4 | 6.0*10-4 | 5.0*10-4 | 4.0*10-4 | 3.5*10-4 | 3.0*10-4 | 2.5*10-4 | 2.0*10-4 |